• By Best Solar Company PK
  • 01 Nov, 2026
  • Net Metering
  • 8 min read

If you installed rooftop solar in Pakistan expecting your summer surplus to quietly pay your winter bills, the rules just changed under you. Since NEPRA notified the **Prosumer Regulations 2026** on 9 February 2026, new solar consumers no longer get annual unit banking. Instead, **net billing uses monthly settlement**—and that single shift is why your sun-soaked June credits will never show up on your foggy December invoice.

This is the most misunderstood part of the new system. Let's break down exactly how monthly settlement differs from the old annual carry-forward, what it costs you in rupees, and why a correctly sized battery is now the real fix.

How the Old System Banked Your Units

Under the repealed Net Metering Regulations 2015, your meter did simple arithmetic. Every exported unit cancelled an imported unit, one-for-one, at the same tariff. Surplus units rolled forward on a quarterly basis and, in practice, let households bank generation across seasons—big summer exports offset the leaner winter months.

That worked beautifully for Pakistan's climate. Long, bright summer days plus heavy daytime generation meant most systems produced far more than they used at noon. Those banked units became a cushion for December and January, when daylight shrinks and panels underperform.

The old model let the grid act like a free, year-long battery. Net billing's monthly settlement quietly repossessed that battery—and now sells your power back to you at full price.

What Monthly Settlement Actually Changes

Net billing breaks the one-for-one link completely. Two separate prices now apply:

  • **Electricity you import** is billed at the prevailing applicable tariff—for most unprotected households that is roughly Rs 40–60+ per unit after fuel adjustments, surcharges and 18% GST.
  • **Electricity you export** is bought back at the National Average Energy Price—now around **Rs 11 per unit** for new consumers, down sharply from the roughly Rs 25.9 per unit existing contracts enjoyed.

Crucially, the account settles **at the end of each 30-day billing cycle**. Existing registered prosumers see their export units credited for just one month instead of three; new applicants get no meaningful carry-forward at all. When the cycle closes, any surplus is cashed out at that low buyback rate—not stored as units for a future month.

So your massive May and June export is converted to rupees at Rs 11 immediately. Then in December, when your panels fall short, you buy top-up power at the full retail tariff. You are selling low and buying high, every single season.

The Seasonal Gap, in Rupees

Here is the asymmetry that hurts. Suppose a Lahore home exports 300 surplus units in a strong summer month and later imports 300 units during a weak winter month.

| Scenario | Summer export value | Winter import cost | Net position | |---|---|---|---| | Old net metering (banking) | 300 units carried forward | 300 units offset 1:1 | ≈ Rs 0 | | New net billing (monthly) | 300 × Rs 11 = Rs 3,300 | 300 × ~Rs 50 = Rs 15,000 | **−Rs 11,700** |

Same house, same panels, same units—but roughly **Rs 11,700 worse off** in this simplified example, purely because the credit no longer banks and the two prices no longer match. Multiply that across a year and payback periods that once sat near 3 years now stretch toward 6–7 years. NEPRA's own transition affects Pakistan's 466,000-plus solar consumers, and industry analysts expect it to push households toward storage. For the underlying rate detail, see our breakdown of the net billing buyback rate.

Why Battery Sizing Is the Real Fix

If the grid will no longer bank your units at fair value, the answer is to **stop exporting cheaply and start self-consuming**. A battery lets you capture midday surplus and discharge it in the evening and early morning—exactly the hours you would otherwise import at Rs 50 per unit.

The economics now favour storage. Every unit you self-consume avoids a ~Rs 50 import. Every unit you are forced to export earns only Rs 11. That Rs 39 per-unit gap is what a battery recovers for you.

**Practical sizing for a Pakistani home:**

  • Calculate your *evening and night* load—typically 40–60% of daily consumption (lights, fans, fridge, one AC, phone charging).
  • Size the battery to cover that window, not your whole day. A usable **5 kWh** bank suits a modest home; **10 kWh** fits a larger house running an AC after sunset.
  • Match the battery to the surplus your panels actually dump at midday—oversizing wastes capital, undersizing still forces cheap exports.

At current prices, LiFePO4 (lithium iron phosphate) storage runs about **Rs 45,000–65,000 per kWh**, averaging near Rs 52,000. That puts a 5 kWh bank around **Rs 262,000** and a 10 kWh bank near **Rs 526,000**. With the right sizing, most homes recover that in 3–4 years through avoided high-tariff imports—then keep the savings for the battery's 8–10 year life. Our full solar battery sizing guide for Pakistan walks through the load-audit maths step by step.

A practical tip from our installs: set your hybrid inverter to **"self-consumption" or "zero-export" priority**, charge the battery first, and release stored power in the 6–11 PM peak. This single setting change, paired with a right-sized bank, slashes both your exports *and* your expensive imports—turning the net billing penalty into a minor rounding error.

Frequently Asked Questions

**Does net billing's monthly settlement affect existing net metering consumers?** Not immediately. NEPRA has grandfathered existing contracts—older prosumers keep their terms (including the higher ~Rs 26 buyback) until their 5- or 7-year agreement expires. The monthly-credit change mainly bites new applicants and those renewing.

**Can I still carry my summer units into winter at all?** No. Under net billing, surplus settles at the close of each 30-day cycle at the ~Rs 11 buyback rate. There is no annual or quarterly bank, so summer generation cannot offset winter imports the way it once did. A battery is the replacement for that lost carry-forward.

**Is solar still worth it in Pakistan under net billing in 2026?** Yes—but the design changes. Grid import tariffs remain high (Rs 40–60+ per unit for most homes), so every unit you self-consume still saves big money. Solar plus a right-sized battery now pays back faster than solar sized only for export.

**How big a battery do I actually need?** Size it to your night-time load, not your total daily use. Most homes land at 5–10 kWh of usable LiFePO4 capacity. Audit your evening appliances first, then match the bank to both that load and your midday surplus.

**Ready to re-engineer your system for net billing?** Talk to the Best Solar Company PK team for a free load audit and a battery-sizing plan built around the 2026 rules—so your solar keeps paying you, not the grid. Learn more in our NEPRA Prosumer Regulations 2026 explainer.

Best Solar Company PK designs and installs reliable solar systems in Rawalpindi, Islamabad, Lahore, Multan, Taunsa Sharif and Karachi. Contact us for a free survey and the best advice for your home or business.